APAR= II09603
ODBC TROUBLESHOOTING - CA400WIN95 CA400WIN CA400OS2OPT  V2.0

*** This is a continuation of II09599 ***

 CONTENTS
 ========
 1.0 ........................ Unable to connect to the AS/400
 2.0 ............................. How to locate the ODBC job
 3.0 .......................................... Common Errors
     3.1 .................................. Connection Errors
     3.2 ........................ Application Specific Errors
     3.3 ............................ Stored Procedure Errors
     3.4 ........................................ Misc Errors
 4.0 ...................... Reporting problems to IBM Support
 5.0 ....................... Diagnostic and Performance Tools
 6.0 ............................................... Security
 7.0 ....................................... Other References
                   3.0 COMMON ERRORS
                   ==================

 3.1  Connection Errors
 ======================

 Undefined Dynalink
 ------------------

 This is a windows error generated when an application fails
 to successfully load a dependent dll.  Either the dll wasn't
 found in the search path or the dll was found but the
 function was not. This is a common problem when the user
 has loaded multiple versions of AS/400 connectivity software.
 Some software vendors load their DLL's in the WINDOWS SYSTEM
 directory.  This is the first directory most applications
 look for to find their DLL's.  If you are switching from a
 OEM product to Client Access, then you will have to remove
 any DLL's that begin with EHN from the WINDOWS SYSTEM
 directory and any other directory in the path that precedes
 the CAWIN or PCS path. If the PC is connected to a network
 file server, keep in mind that network drives are also
 included in the default search path. Windows searches in the
 following order:  Current directory, windows,
 windows/system, PATH, network drives.

 Communication Link Failure APPC RC0x36
 --------------------------------------
 This error message occurs when the Database Server prestart
 job QZDAINIT isn't active or on the system.  Try starting
 it manually using the steps provided above.  If that fails,
 use the "Unable to Connect" checklist provided above.

 Communication Link Failure APPC RC0x32 and  RC0x6
 -------------------------------------------------

 This error may occur when using an SNA connection
 to the AS/400 and passing through a network of other
 AS/400's and VTAM's.  To resolve this
 error, create a QSERVER mode description on all systems
 that the conversation passes Through.  Use the same
 parameters that are specified for the existing QSERVER
 mode description. On an AS/400, issue the following command:

     CRTMODD MODD(QSERVER) MAXSSN(64) MAXCNV(64) LCLCTLSSN(0)
     INPACING(8) OUTPACING(8)

 Ivalid Security APPC RC0x32 or RC0x37
 -------------------------------------

 This error is usually seen when an invalid userid or
 password is supplied on an ODBC connect statement (rather
 then using the default userid of the router).  SA51888 fixed
 a problem in the OS/2 vdm router that incorrectly generated
 this error when running ODBC
 in a winos2 environment across the virtual extended DOS
 router. Obtain the the latest PTF from service for a
 solution.

 Communication Link Failure APPC RC0x46
 --------------------------------------
 This error is caused by the Database Server on the AS/400
 terminating abnormally.  Call your IBM Support Line
 representative to assist in problem determination.
 See GATHERING INFORMATION FOR IBM SUPPORT below for details.

 Communication Link Failure APPC RC0x51
 --------------------------------------

 This results from using an incorrect system name in the
 ODBC data source.  Users of the Windows ODBC driver under
 OS/2 may see this error if they mistakenly used the system
 name instead of the CM/2 (or CM/400) Partner LU ALIAS name.
 Run the Communications Manager configuration program and
 verify the Partner LU Alias name.
 This information can also be found in the RMTN statement of
 the PCSOS2 CONFIG.PCS file.

 APPC RC0x85 or  RC0x87
 -----------------------
 This RC is only defined for the Netsoft router.  Obtain the
 latest router fixes from your vendor (Novell SAA or Netsoft).
 See "Dynalink Error" above for tips on solving duplicate dll
 problems.

 MSGSQL0113 -  Name &1 not allowed.
 ---------------------------------
 See MSGSQL0114

 MSGSQL0114 - Relational database &1 not the same as current
 &2 server
 -----------------------------------------------------------

 o The system name is most likely not added to the Remote
   Database Directory.  Run the following command:

          ADDRDBDIRE RDB(SYSNAME) RMTLOCNAME(*LOCAL)

   Where SYSNAME is the name of your system's Default Local
   Location name (as specified in the DSPNETA command).

 o Another common cause for this error is a period (".") in a
   table or   library name.  Although valid in AS/400 naming
   conventions, this is an invalid character for ODBC and SQL
   syntax.  C  onsider changing file naming conventions to
   conform to AN  SI 92 SQL syntax.
   A short term circumvention may be to build a logical file
   over the desired physical file, using the SQL naming syntax.

 MSGSQL0122 - Column &1 or function specified in SELECT...
 ---------------------------------------------------------

 If there is a GROUP BY clause in the SQL Select statement,
 the same fields that are specified in the GROUP BY must be
 in the SELECT field list.

 MSGSQL0204 - MYSYSCONF not found
 --------------------------------

 This message is always seen in the joblogs for jobs using
 the Microsoft Jet Engine (MS ACCESS or MS Visual Basic
 applications). The MS Jet Engine used by these applications
 always checks for an optional table on the server called
 MSYSCONF. The warning is ignored by the applications.  For
 further information see the MS Jet Database
 Engine Connectivity white paper or contact Microsoft.

 MSGSQL0900 - Application process not in a connected state
 ---------------------------------------------------------
 See SQL5016 and SQL0114.

 MSGSQL5001 - Column qualifier or table &2 undefined.
 MSGSQL5016 - Object name &1 not valid for naming convention
 ------------------------------------------------------------
 Your Data Source Name (DSN) is incorrectly configured to
 use the wrong naming convention.  Use the ODBC Administrator
 to change your DSN to use the proper (*SQL or *SYS) naming
 convention. "*SQL" should always be used unless your
 application is specifically designed for *SYS.


 MSGSQL0104  Token &1 was not valid. Valid tokens: &2.
 -----------------------------------------------------

  -  The application generated a SQL statement with incorrect
     syntax.
  -  If the token is "*" see SQL0114.
  -  ODBC.DLL is down level.  See "Conformance Error -7716".
  -  The SQL statement exceeded the AS/400's 32K size
     limitation.
  -  The application is using incorrect syntax for left outer
     join. Some applications default to a proprietary left
     outer join syntax of     *= in the WHERE clause
     (Powerbuilder 3.0 & 4.0, Cry stal Reports).
     Check with your application vendor.  Most provide an
     ini setting     or configuration value to use ODBC left
     outer join syntax.

 MSGSQL7008  &1 in &2 not valid for operation.  The reason
 code is 3.
 ------------------------------------------------------------


 MSGSQL7008  &1 in &2 not valid for operation.  The reason
 code is 3.
 ------------------------------------------------------------

 The AS/400 implements commitment control by journaling.
 Any ODBC application that takes advantage of commitment
 control will require that the files used be journaled.
 See APAR SA49616 for detailed information.  SA49616
 specifically addresses coexistence issues with COGNOS
 Impromptu.  It also provides general information on
 commitment control and how i
 t relates to
 journaling.

 3.2 APPLICATION SPECIFIC ERRORS
 ================================

 3.2.1 CONFORMANCE ERRORS with Microsoft Access
 ==============================================

 -   -7711

     o Router not started.
     o Incorrect naming convention used (see SQL5016).
     o A library specified in the ODBC Data Source does not
       exist on the AS/400.  Use the ODBC administration
       program to reconfigure the driver.
     o Duplicate EHNAPPC dll's or mixed versions of
       connectivity code. See "Dynalink Error".
     o If using the Client Access for Windows 3.1 ODBC driver
       with the Client Access for extended DOS router, verify
       that Client Access has been configured for Windows
       coexistence: i.e. the PCSWIN TSR is loaded before
       loading windows.

 -   -7716

     o If this occurs when using an OEM router or the  Client
       Access for Extended DOS router, then obtain the latest
       ODBC host server PTF.
     o If using Client Access for Windows 3.11 or later ODBC
       driver, then verify that the ODBC driver manager
       (ODBC.DLL) is at version 2 of the ODBC specification.
       The size and date of ODBC.DLL and ODBCADM.DLL in your
       windows system directory should match those in the
       AS/400 directory  QPWXCWN.

 -   -7738

     o If this error occurs when accessing a physical file
       with logical files built over it, try copying the
       physical file to a new library and querying that file.
       If this works, there is a problem with with the logical
       files built over the physical file.  See apar SA45547
       for the latest ODBC host server PTF and contact AS/400
       technical support for any additional PTFs that may be
       required to run with it.
     o If the latest PTFs are applied, and you still get the
       -7738 error, it is possible that an index over the
       physical file is corrupted and will need to be rebuilt.
       If accessing a physical file that has a join logical
       file over it, the join logical file may not be keyed.

 -   -7761

     The Client Access for Windows R311 ODBC driver was
     updated to return full support ("F") for left outer
     join support. This value was added in the R2 ODBC
     specification. Older versions of the MS Jet Engine
     included with MS ACCE SS report this as a 7761
     conformance error: "valid values are only Y or N".
     Obtain the latest Jet Engine fix pack from microsoft
     support.

 -   Missing data or Incorrect Data

     o ACCESS may not display all fields if the total number
       exceeds 200 fields.  Contact Microsoft support for
       further in formation on record size limitations with
       MS ACCESS 2.0.

 -   o ACCESS may implement left outer joins by splitting
       the statement into two separate selects, downloading
       all the data, and then joining the two temporary
       tables. This can potentially lead to EXTREMELY large
       temporary files and unpredictable results. Contact
       Microsoft for information on how ACCESS can take
       advantage of full left outs which the AS/400 supports.

 3.2.2 DELPHI ISSUES
 ===================

 Incorrect number of rows returned on select.
 --------------------------------------------

     Apply SF29383 or later.  See SA48157 for a detailed
     description.

 *** Please see II09604 for the continuation of this APAR ***



 See "Dynalink Error" above for tips on solving duplicate dll
 problems.